A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise.
Metrics
Affected Vendors & Products
References
History
Wed, 12 Mar 2025 19:15:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Weaknesses | CWE-200 | |
Metrics |
cvssV3_1
|
Thu, 13 Feb 2025 22:45:00 +0000
Type | Values Removed | Values Added |
---|---|---|
Description | A critical information disclosure vulnerability exists in the web-based management interface of GatesAir Maxiva UAXT, VAXT transmitters due to Incorrect Access Control (CWE-284). Unauthenticated attackers can directly access sensitive database backup files (snapshot_users.db) via publicly exposed URLs (/logs/devcfg/snapshot/ and /logs/devcfg/user/). Exploiting this vulnerability allows retrieval of sensitive user data, including login credentials, potentially leading to full system compromise. | |
References |
|

Status: PUBLISHED
Assigner: mitre
Published: 2025-02-13T00:00:00.000Z
Updated: 2025-03-12T18:56:37.678Z
Reserved: 2025-01-09T00:00:00.000Z
Link: CVE-2025-22961

Updated: 2025-02-19T16:03:31.277Z

Status : Awaiting Analysis
Published: 2025-02-13T23:15:11.047
Modified: 2025-03-12T19:15:38.433
Link: CVE-2025-22961

No data.