Total
145 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2020-7846 | 1 Cnesty | 1 Helpcom | 2024-11-21 | 8 High |
Helpcom before v10.0 contains a file download and execution vulnerability caused by storing hardcoded cryptographic key. It finally leads to a file download and execution via access to crafted web page. | ||||
CVE-2020-6990 | 1 Rockwellautomation | 6 Micrologix 1100, Micrologix 1100 Firmware, Micrologix 1400 and 3 more | 2024-11-21 | 9.8 Critical |
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller. | ||||
CVE-2020-6983 | 1 Moxa | 110 Pt-7528-12msc-12tx-4gsfp-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv, Pt-7528-12msc-12tx-4gsfp-hv-hv Firmware and 107 more | 2024-11-21 | 7.5 High |
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered. | ||||
CVE-2020-6979 | 1 Moxa | 4 Eds-510e, Eds-510e Firmware, Eds-g516e and 1 more | 2024-11-21 | 7.5 High |
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered. | ||||
CVE-2020-2500 | 1 Qnap | 1 Helpdesk | 2024-11-21 | 9.8 Critical |
This improper access control vulnerability in Helpdesk allows attackers to get control of QNAP Kayako service. Attackers can access the sensitive data on QNAP Kayako server with API keys. We have replaced the API key to mitigate the vulnerability, and already fixed the issue in Helpdesk 3.0.1 and later versions. | ||||
CVE-2020-28395 | 1 Siemens | 16 Scalance Xr324-12m, Scalance Xr324-12m Firmware, Scalance Xr324-12m Ts and 13 more | 2024-11-21 | 5.9 Medium |
A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic. | ||||
CVE-2020-28391 | 1 Siemens | 132 Scalance X200-4pirt, Scalance X200-4pirt Firmware, Scalance X201-3pirt and 129 more | 2024-11-21 | 5.9 Medium |
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic. | ||||
CVE-2020-25688 | 1 Redhat | 2 Acm, Advanced Cluster Management For Kubernetes | 2024-11-21 | 3.5 Low |
A flaw was found in rhacm versions before 2.0.5 and before 2.1.0. Two internal service APIs were incorrectly provisioned using a test certificate from the source repository. This would result in all installations using the same certificates. If an attacker could observe network traffic internal to a cluster, they could use the private key to decode API requests that should be protected by TLS sessions, potentially obtaining information they would not otherwise be able to. These certificates are not used for service authentication, so no opportunity for impersonation or active MITM attacks were made possible. | ||||
CVE-2020-25234 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2024-11-21 | 7.7 High |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The LOGO! program files generated and used by the affected components offer the possibility to save user-defined functions (UDF) in a password protected way. This protection is implemented in the software that displays the information. An attacker could reverse engineer the UDFs directly from stored program files. | ||||
CVE-2020-25233 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2024-11-21 | 5.5 Medium |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The firmware update of affected devices contains the private RSA key that is used as a basis for encryption of communication with the device. | ||||
CVE-2020-25231 | 1 Siemens | 3 Logo\! 8 Bm, Logo\! 8 Bm Firmware, Logo\! Soft Comfort | 2024-11-21 | 5.5 Medium |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3), LOGO! Soft Comfort (All versions < V8.3). The encryption of program data for the affected devices uses a static key. An attacker could use this key to extract confidential information from protected program files. | ||||
CVE-2020-25229 | 1 Siemens | 2 Logo\! 8 Bm, Logo\! 8 Bm Firmware | 2024-11-21 | 7.5 High |
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). The implemented encryption for communication with affected devices is prone to replay attacks due to the usage of a static key. An attacker could change the password or change the configuration on any affected device if using prepared messages that were generated for another device. | ||||
CVE-2020-25193 | 1 Ge | 6 Rt430, Rt430 Firmware, Rt431 and 3 more | 2024-11-21 | 5.3 Medium |
By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. | ||||
CVE-2020-25180 | 3 Rockwellautomation, Schneider-electric, Xylem | 31 Aadvance Controller, Isagraf Free Runtime, Isagraf Runtime and 28 more | 2024-11-21 | 5.3 Medium |
Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. | ||||
CVE-2020-25173 | 1 Reolink | 14 Rlc-410, Rlc-410 Firmware, Rlc-422 and 11 more | 2024-11-21 | 7.8 High |
An attacker with local network access can obtain a fixed cryptography key which may allow for further compromise of Reolink P2P cameras outside of local network access | ||||
CVE-2020-1764 | 2 Kiali, Redhat | 3 Kiali, Openshift Service Mesh, Service Mesh | 2024-11-21 | 8.6 High |
A hard-coded cryptographic key vulnerability in the default configuration file was found in Kiali, all versions prior to 1.15.1. A remote attacker could abuse this flaw by creating their own JWT signed tokens and bypass Kiali authentication mechanisms, possibly gaining privileges to view and alter the Istio configuration. | ||||
CVE-2020-10884 | 1 Tp-link | 2 Ac1750, Ac1750 Firmware | 2024-11-21 | 8.8 High |
This vulnerability allows network-adjacent attackers execute arbitrary code on affected installations of TP-Link Archer A7 Firmware Ver: 190726 AC1750 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the tdpServer service, which listens on UDP port 20002 by default. This issue results from the use of hard-coded encryption key. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of root. Was ZDI-CAN-9652. | ||||
CVE-2019-7594 | 1 Johnsoncontrols | 1 Metasys System | 2024-11-21 | N/A |
Metasys® ADS/ADX servers and NAE/NIE/NCE engines prior to 9.0 make use of a hardcoded RC2 key for certain encryption operations involving the Site Management Portal (SMP). | ||||
CVE-2019-5137 | 1 Moxa | 2 Awk-3131a, Awk-3131a Firmware | 2024-11-21 | 7.5 High |
The usage of hard-coded cryptographic keys within the ServiceAgent binary allows for the decryption of captured traffic across the network from or to the Moxa AWK-3131A firmware version 1.13. | ||||
CVE-2019-19754 | 2024-11-21 | 5.7 Medium | ||
HiveOS through 0.6-102@191212 ships with SSH host keys baked into the installation image, which allows man-in-the-middle attacks and makes identification of all public IPv4 nodes trivial with Shodan.io. NOTE: as of 2019-09-26, the vendor indicated that they would consider fixing this. |