CVE-2021-27440 | 1 Ge | 2 Reason Dr60, Reason Dr60 Firmware | 2024-11-21 | 9.8 Critical |
The software contains a hard-coded password it uses for its own inbound authentication or for outbound communication to external components on the Reason DR60 (all firmware versions prior to 02A04.1). | ||||
CVE-2021-27254 | 1 Netgear | 86 Br200, Br200 Firmware, Br500 and 83 more | 2024-11-21 | 8.8 High |
This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of NETGEAR R7800. Authentication is not required to exploit this vulnerability. The specific flaw exists within the apply_save.cgi endpoint. This issue results from the use of hard-coded encryption key. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-12287. | ||||
CVE-2021-22729 | 1 Schneider-electric | 12 Evlink City Evc1s22p4, Evlink City Evc1s22p4 Firmware, Evlink City Evc1s7p4 and 9 more | 2024-11-21 | 9.8 Critical |
A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized administrative privileges when accessing to the charging station web server. | ||||
CVE-2021-21818 | 1 Dlink | 2 Dir-3040, Dir-3040 Firmware | 2024-11-21 | 7.5 High |
A hard-coded password vulnerability exists in the Zebra IP Routing Manager functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to a denial of service. An attacker can send a sequence of requests to trigger this vulnerability. | ||||
CVE-2020-7590 | 1 Siemens | 2 Dca Vantage Analyzer, Dca Vantage Analyzer Firmware | 2024-11-21 | 6.8 Medium |
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Affected devices use a hard-coded password to protect the onboard database. This could allow an attacker to read and or modify the onboard database. Successful exploitation requires direct physical access to the device. | ||||
CVE-2020-5351 | 1 Dell | 1 Emc Data Protection Advisor | 2024-11-21 | 7.5 High |
Dell EMC Data Protection Advisor versions 6.4, 6.5 and 18.1 contain an undocumented account with limited privileges that is protected with a hard-coded password. A remote unauthenticated malicious user with the knowledge of the hard-coded password may login to the system and gain read-only privileges. | ||||
CVE-2020-2499 | 1 Qnap | 1 Qes | 2024-11-21 | 6.3 Medium |
A hard-coded password vulnerability has been reported to affect earlier versions of QES. If exploited, this vulnerability could allow attackers to log in with a hard-coded password. QNAP has already fixed the issue in QES 2.1.1 Build 20200515 and later. | ||||
CVE-2020-12047 | 1 Baxter | 3 Sigma Spectrum Infusion System, Sigma Spectrum Infusion System Firmware, Wireless Battery Module | 2024-11-21 | 9.8 Critical |
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials. | ||||
CVE-2020-12045 | 1 Baxter | 3 Sigma Spectrum Infusion System, Sigma Spectrum Infusion System Firmware, Wireless Battery Module | 2024-11-21 | 9.8 Critical |
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. | ||||
CVE-2020-12039 | 1 Baxter | 2 Sigma Spectrum Infusion System, Sigma Spectrum Infusion System Firmware | 2024-11-21 | 2.4 Low |
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed. | ||||
CVE-2020-12037 | 1 Baxter | 4 Prismaflex, Prismaflex Firmware, Prismax and 1 more | 2024-11-21 | 7.5 High |
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The affected devices do not implement data-in-transit encryption (e.g., TLS/SSL) when configured to send treatment data to a PDMS (Patient Data Management System) or an EMR (Electronic Medical Record) system. An attacker could observe sensitive data sent from the device. | ||||
CVE-2020-12016 | 1 Baxter | 4 Em1200, Em1200 Firmware, Em2400 and 1 more | 2024-11-21 | 9.8 Critical |
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI. | ||||
CVE-2020-12012 | 1 Baxter | 4 Em1200, Em1200 Firmware, Em2400 and 1 more | 2024-11-21 | 6.1 Medium |
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix application. Successful exploitation of this vulnerability may allow an attacker with physical access to gain unauthorized access to view/update system configuration or data. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI. | ||||
CVE-2019-3908 | 1 Identicard | 1 Premisys Id | 2024-11-21 | 7.5 High |
Premisys Identicard version 3.1.190 stores backup files as encrypted zip files. The password to the zip is hard-coded and unchangeable. An attacker with access to these backups can decrypt them and obtain sensitive data. | ||||
CVE-2019-13530 | 1 Philips | 19 865240, 865241, 865242 and 16 more | 2024-11-21 | 7.2 High |
Philips IntelliVue WLAN, portable patient monitors, WLAN Version A, Firmware A.03.09, WLAN Version A, Firmware A.03.09, Part #: M8096-67501, WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C) and WLAN Version B, Firmware A.01.09, Part #: N/A (Replaced by Version C). An attacker can use these credentials to login via ftp and upload a malicious firmware. | ||||
CVE-2019-10881 | 1 Xerox | 20 Altalink B8045, Altalink B8045 Firmware, Altalink B8055 and 17 more | 2024-11-21 | 9.8 Critical |
Xerox AltaLink B8045/B8055/B8065/B8075/B8090, AltaLink C8030/C8035/C8045/C8055/C8070 with software releases before 103.xxx.030.32000 includes two accounts with weak hard-coded passwords which can be exploited and allow unauthorized access which cannot be disabled. | ||||
CVE-2018-8870 | 1 Medtronic | 4 24950 Mycarelink Monitor, 24950 Mycarelink Monitor Firmware, 24952 Mycarelink Monitor and 1 more | 2024-11-21 | N/A |
Medtronic MyCareLink Patient Monitor, 24950 MyCareLink Monitor, all versions, and 24952 MyCareLink Monitor, all versions contains a hard-coded operating system password. An attacker with physical access can remove the case of the device, connect to the debug port, and use the password to gain privileged access to the operating system. | ||||
CVE-2017-6039 | 1 Phoenixbroadband | 2 Poweragent Sc3 Bms, Poweragent Sc3 Bms Firmware | 2024-11-21 | N/A |
A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded password may allow unauthorized access to the device. | ||||
CVE-2017-6022 | 1 Bd | 2 Kla Journal Service, Performa | 2024-11-21 | N/A |
A hard-coded password issue was discovered in Becton, Dickinson and Company (BD) PerformA, Version 2.0.14.0 and prior versions, and KLA Journal Service, Version 1.0.51 and prior versions. They use hard-coded passwords to access the BD Kiestra Database, which could be leveraged to compromise the confidentiality of limited PHI/PII information stored in the BD Kiestra Database. | ||||
CVE-2017-20039 | 1 Sicunet | 1 Access Control | 2024-11-21 | 9.8 Critical |
A vulnerability was found in SICUNET Access Controller 0.32-05z. It has been classified as very critical. This affects an unknown part. The manipulation leads to weak authentication. It is possible to initiate the attack remotely. |