Filtered by vendor Tenda Subscriptions
Total 1159 CVE
CVE Vendors Products Updated CVSS v3.1
CVE-2022-37815 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the PPPOEPassword parameter in the function formQuickIndex.
CVE-2022-37814 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain multiple stack overflows via the deviceMac and the device_id parameters in the function addWifiMacFilter.
CVE-2022-37813 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromSetSysTime.
CVE-2022-37812 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the firewallEn parameter in the function formSetFirewallCfg.
CVE-2022-37811 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the startIp parameter in the function formSetPPTPServer.
CVE-2022-37810 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a command injection vulnerability via the mac parameter in the function formWriteFacMac.
CVE-2022-37809 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the speed_dir parameter in the function formSetSpeedWan.
CVE-2022-37808 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the index parameter in the function formWifiWpsOOB.
CVE-2022-37807 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function formSetClientState.
CVE-2022-37806 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromDhcpListClient.
CVE-2022-37805 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the function fromWizardHandle.
CVE-2022-37804 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the time parameter in the function saveParentControlInfo.
CVE-2022-37803 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromAddressNat.
CVE-2022-37802 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the page parameter in the function fromNatStaticSetting.
CVE-2022-37801 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function formSetQosBand.
CVE-2022-37800 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function fromSetRouteStatic.
CVE-2022-37799 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the time parameter at the function setSmartPowerManagement.
CVE-2022-37798 1 Tenda 2 Ac1206, Ac1206 Firmware 2024-11-21 9.8 Critical
Tenda AC1206 V15.03.06.23 was discovered to contain a stack overflow via the list parameter at the function formSetVirtualSer.
CVE-2022-37292 1 Tenda 2 Ax12, Ax12 Firmware 2024-11-21 5.5 Medium
Tenda AX12 V22.03.01.21_CN is vulnerable to Buffer Overflow. This overflow is triggered in the sub_42FDE4 function, which satisfies the request of the upper-level interface function sub_430124, that is, handles the post request under /goform/SetIpMacBind.
CVE-2022-37175 1 Tenda 2 Ac15, Ac15 Firmware 2024-11-21 9.8 Critical
Tenda ac15 firmware V15.03.05.18 httpd server has stack buffer overflow in /goform/formWifiBasicSet.