Total
2241 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2024-32288 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 6.3 Medium |
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function. | ||||
CVE-2024-32287 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 6.5 Medium |
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the qos parameter in the fromqossetting function. | ||||
CVE-2024-32285 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 8 High |
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function. | ||||
CVE-2024-26710 | 1 Linux | 1 Linux Kernel | 2025-03-17 | 5.5 Medium |
In the Linux kernel, the following vulnerability has been resolved: powerpc/kasan: Limit KASAN thread size increase to 32KB KASAN is seen to increase stack usage, to the point that it was reported to lead to stack overflow on some 32-bit machines (see link). To avoid overflows the stack size was doubled for KASAN builds in commit 3e8635fb2e07 ("powerpc/kasan: Force thread size increase with KASAN"). However with a 32KB stack size to begin with, the doubling leads to a 64KB stack, which causes build errors: arch/powerpc/kernel/switch.S:249: Error: operand out of range (0x000000000000fe50 is not between 0xffffffffffff8000 and 0x0000000000007fff) Although the asm could be reworked, in practice a 32KB stack seems sufficient even for KASAN builds - the additional usage seems to be in the 2-3KB range for a 64-bit KASAN build. So only increase the stack for KASAN if the stack size is < 32KB. | ||||
CVE-2024-32313 | 1 Tenda | 2 Fh1205, Fh1205 Firmware | 2025-03-17 | 6.5 Medium |
Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the adslPwd parameter of the formWanParameterSetting function. | ||||
CVE-2024-32307 | 1 Tenda | 2 Fh1205, Fh1205 Firmware | 2025-03-17 | 7.4 High |
Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function. | ||||
CVE-2024-32310 | 1 Tenda | 2 F1203, F1203 Firmware | 2025-03-17 | 8 High |
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function. | ||||
CVE-2024-32312 | 1 Tenda | 2 F1203, F1203 Firmware | 2025-03-17 | 5.7 Medium |
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function. | ||||
CVE-2024-32311 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-03-17 | 6.5 Medium |
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function. | ||||
CVE-2024-32299 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-03-17 | 8.8 High |
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the PPW parameter in the fromWizardHandle function. | ||||
CVE-2024-32316 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | 6.5 Medium |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability in the fromDhcpListClient function. | ||||
CVE-2024-32318 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | 9.8 Critical |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the vlan parameter in the formSetVlanInfo function. | ||||
CVE-2024-32320 | 1 Tenda | 2 Ac500, Ac500 Firmware | 2025-03-17 | 5.9 Medium |
Tenda AC500 V2.0.1.9(1307) firmware has a stack overflow vulnerability via the timeZone parameter in the formSetTimeZone function. | ||||
CVE-2024-33215 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | 9.8 Critical |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/addressNat. | ||||
CVE-2024-33212 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | 8.8 High |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter in ip/goform/setcfm. | ||||
CVE-2024-33211 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | 7.3 High |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the PPPOEPassword parameter in ip/goform/QuickIndex. | ||||
CVE-2024-33213 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | 6.5 Medium |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the mitInterface parameter in ip/goform/RouteStatic. | ||||
CVE-2024-33217 | 1 Tenda | 2 Fh1206, Fh1206 Firmware | 2025-03-17 | 7.5 High |
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parameter in ip/goform/addressNat. | ||||
CVE-2024-35580 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | 9.8 Critical |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the adv.iptv.stbpvid parameter in the function formSetIptv. | ||||
CVE-2024-35579 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-03-17 | 7.7 High |
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.city.vlan parameter in the function formSetIptv. |