CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2022-28702 | 1 Abb | 1 E-design | 2024-11-21 | 6.1 Medium |
Incorrect Default Permissions vulnerability in ABB e-Design allows attacker to install malicious software executing with SYSTEM permissions violating confidentiality, integrity, and availability of the target machine. | ||||
CVE-2022-28613 | 2 Abb, Hitachienergy | 3 Rtu500 Firmware, Rtu500, Rtu500 Firmware | 2024-11-21 | 7.5 High |
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function. | ||||
CVE-2022-26057 | 1 Abb | 1 Mint Workbench | 2024-11-21 | 6.7 Medium |
Vulnerabilities in the Mint WorkBench allow a low privileged attacker to create and write to a file anywhere on the file system as SYSTEM with arbitrary content as long as the file does not already exist. The Mint WorkBench installer file allows a low-privileged user to run a "repair" operation on the product | ||||
CVE-2022-1596 | 1 Abb | 6 Rex640 Pcl1, Rex640 Pcl1 Firmware, Rex640 Pcl2 and 3 more | 2024-11-21 | 6.5 Medium |
Incorrect Permission Assignment for Critical Resource vulnerability in ABB REX640 PCL1, REX640 PCL2, REX640 PCL3 allows an authenticated attacker to launch an attack against the user database file and try to take control of an affected system node. | ||||
CVE-2022-0947 | 1 Abb | 48 Arc600a2323na, Arc600a2323na Firmware, Arc600a2324na and 45 more | 2024-11-21 | 9 Critical |
A vulnerability in ABB ARG600 Wireless Gateway series that could allow an attacker to exploit the vulnerability by remotely connecting to the serial port gateway, and/or protocol converter, depending on the configuration. | ||||
CVE-2022-0902 | 1 Abb | 14 Rmc-100, Rmc-100-lite, Rmc-100-lite Firmware and 11 more | 2024-11-21 | 8.1 High |
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in flow computer and remote controller products of ABB ( RMC-100 (Standard), RMC-100-LITE, XIO, XFCG5 , XRCG5 , uFLOG5 , UDC) allows an attacker who successfully exploited this vulnerability could insert and run arbitrary code in an affected system node. | ||||
CVE-2021-22288 | 1 Abb | 4 Pni800, Pni800 Firmware, Spiet800 and 1 more | 2024-11-21 | 7.5 High |
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive. | ||||
CVE-2021-22286 | 1 Abb | 4 Pni800, Pni800 Firmware, Spiet800 and 1 more | 2024-11-21 | 7.5 High |
Improper Input Validation vulnerability in the ABB SPIET800 and PNI800 module allows an attacker to cause the denial of service or make the module unresponsive. | ||||
CVE-2021-22285 | 1 Abb | 4 Pni800, Pni800 Firmware, Spiet800 and 1 more | 2024-11-21 | 7.5 High |
Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive. | ||||
CVE-2021-22284 | 1 Abb | 1 Opc Server For Ac 800m | 2024-11-21 | 8.4 High |
Incorrect Permission Assignment for Critical Resource vulnerability in OPC Server for AC 800M allows an attacker to execute arbitrary code in the node running the AC800M OPC Server. | ||||
CVE-2021-22279 | 1 Abb | 2 Omnicore C30, Omnicore C30 Firmware | 2024-11-21 | 9.8 Critical |
A Missing Authentication vulnerability in RobotWare for the OmniCore robot controller allows an attacker to read and modify files on the robot controller if the attacker has access to the Connected Services Gateway Ethernet port. | ||||
CVE-2021-22278 | 2 Abb, Hitachienergy | 2 Update Manager, Pcm600 | 2024-11-21 | 6.7 Medium |
A certificate validation vulnerability in PCM600 Update Manager allows attacker to get unwanted software packages to be installed on computer which has PCM600 installed. | ||||
CVE-2021-22277 | 1 Abb | 4 800xa, Base Software, Compact Product Suite and 1 more | 2024-11-21 | 7.5 High |
Improper Input Validation vulnerability in ABB 800xA, Control Software for AC 800M, Control Builder Safe, Compact Product Suite - Control and I/O, ABB Base Software for SoftControl allows an attacker to cause the denial of service. | ||||
CVE-2021-22276 | 1 Abb | 10 System Access Point 127v, System Access Point 127v Firmware, System Access Point 2.0 and 7 more | 2024-11-21 | 6.1 Medium |
The vulnerability allows a successful attacker to bypass the integrity check of FW uploaded to the free@home System Access Point. | ||||
CVE-2021-22272 | 2 Abb, Busch-jaeger | 2 Mybuildings, Mybusch-jaeger | 2024-11-21 | 6.5 Medium |
The vulnerability origins in the commissioning process where an attacker of the ControlTouch can enter a serial number in a specific way to transfer the device virtually into her/his my.busch-jaeger.de or mybuildings.abb.com profile. A successful attacker can observe and control a ControlTouch remotely under very specific circumstances. The issue is fixed in the cloud side of the system. No firmware update is needed for customer products. If a user wants to understand if (s)he is affected, please read the advisory. This issue affects: ABB and Busch-Jaeger, ControlTouch | ||||
CVE-2020-8489 | 1 Abb | 1 800xa Information Management | 2024-11-21 | 7.8 High |
Insufficient protection of the inter-process communication functions in ABB System 800xA Information Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting the runtime values to be stored in the archive, or making Information Management history services unavailable. | ||||
CVE-2020-8488 | 1 Abb | 1 800xa Batch Management | 2024-11-21 | 7.8 High |
Insufficient protection of the inter-process communication functions in ABB System 800xA Batch Management (all published versions) enables an attacker authenticated on the local system to inject data, affecting User Interface update during batch execution and/or compare/printing functionalities. | ||||
CVE-2020-8487 | 1 Abb | 1 800xa Base System | 2024-11-21 | 6.6 Medium |
Insufficient protection of the inter-process communication functions in ABB System 800xA Base (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. | ||||
CVE-2020-8486 | 1 Abb | 1 800xa Rnrp | 2024-11-21 | 6.6 Medium |
Insufficient protection of the inter-process communication functions in ABB System 800xA RNRP (all published versions) enables an attacker authenticated on the local system to inject data, affect node redundancy handling. | ||||
CVE-2020-8485 | 1 Abb | 1 800xa | 2024-11-21 | 7.8 High |
Insufficient protection of the inter-process communication functions in ABB System 800xA for MOD 300 (all published versions) enables an attacker authenticated on the local system to inject data, allowing reads and writes to the controllers or cause windows processes to crash. |