Filtered by vendor Tenda
Subscriptions
Total
1159 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2025-25668 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | 9.8 Critical |
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_47D878 function. | ||||
CVE-2024-32293 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 8 High |
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromDhcpListClient function. | ||||
CVE-2024-32292 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 8.8 High |
Tenda W30E v1.0 V1.0.1.25(633) firmware contains a command injection vulnerablility in the formexeCommand function via the cmdinput parameter. | ||||
CVE-2024-32291 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 7.5 High |
Tenda W30E v1.0 firmware v1.0.1.25(633) has a stack overflow vulnerability via the page parameter in the fromNatlimit function. | ||||
CVE-2024-32290 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 6.7 Medium |
Tenda W30E v1.0 v1.0.1.25(633) firmware has a stack overflow vulnerability via the page parameter in the fromAddressNat function. | ||||
CVE-2024-32288 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 6.3 Medium |
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromwebExcptypemanFilter function. | ||||
CVE-2024-32287 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 6.5 Medium |
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the qos parameter in the fromqossetting function. | ||||
CVE-2024-32286 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 9.8 Critical |
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability located via the page parameter in the fromVirtualSer function. | ||||
CVE-2024-32285 | 1 Tenda | 2 W30e, W30e Firmware | 2025-03-17 | 8 High |
Tenda W30E v1.0 V1.0.1.25(633) firmware has a stack overflow vulnerability via the password parameter in the formaddUserName function. | ||||
CVE-2025-25664 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | 9.8 Critical |
Tenda AC8V4 V16.03.34.06 was discovered to contain a stack overflow via the shareSpeed parameter in the sub_49E098 function. | ||||
CVE-2025-25663 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | 9.8 Critical |
A vulnerability was found in Tenda AC8V4 V16.03.34.06. Affected is the function SUB_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. | ||||
CVE-2024-32313 | 1 Tenda | 2 Fh1205, Fh1205 Firmware | 2025-03-17 | 6.5 Medium |
Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the adslPwd parameter of the formWanParameterSetting function. | ||||
CVE-2024-32307 | 1 Tenda | 2 Fh1205, Fh1205 Firmware | 2025-03-17 | 7.4 High |
Tenda FH1205 V2.0.0.7(775) firmware has a stack overflow vulnerability located via the PPW parameter in the fromWizardHandle function. | ||||
CVE-2024-57704 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | 4.6 Medium |
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime leads to stack-based buffer overflow. | ||||
CVE-2024-46652 | 1 Tenda | 3 Ac8, Ac8 Firmware, Ac8v4 Firmware | 2025-03-17 | 9.8 Critical |
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability in the fromAdvSetMacMtuWan function. | ||||
CVE-2024-57703 | 1 Tenda | 2 Ac8, Ac8 Firmware | 2025-03-17 | 7.3 High |
Tenda AC8v4 V16.03.34.06 has a stack overflow vulnerability. Affected by this vulnerability is the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedEndTime leads to stack-based buffer overflow. | ||||
CVE-2024-32310 | 1 Tenda | 2 F1203, F1203 Firmware | 2025-03-17 | 8 High |
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function. | ||||
CVE-2024-32312 | 1 Tenda | 2 F1203, F1203 Firmware | 2025-03-17 | 5.7 Medium |
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function. | ||||
CVE-2024-32283 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-03-17 | 7.3 High |
Tenda FH1203 V2.0.1.6 firmware has a command injection vulnerablility in formexeCommand function via the cmdinput parameter. | ||||
CVE-2024-32311 | 1 Tenda | 2 Fh1203, Fh1203 Firmware | 2025-03-17 | 6.5 Medium |
Tenda FH1203 v2.0.1.6 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function. |