CVE-2024-52949 2025-01-29 9.8 Critical
iptraf-ng 1.2.1 has a stack-based buffer overflow. In src/ifaces.c, the strcpy function consistently fails to control the size, and it is consequently possible to overflow memory on the stack.
CVE-2024-7994 1 Autodesk 1 Revit 2025-01-28 7.8 High
A maliciously crafted RFA file, when parsed through Autodesk Revit, can force a Stack-Based Buffer Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.
CVE-2024-37008 1 Autodesk 2 Revit, Revit Lt 2025-01-28 7.8 High
A maliciously crafted DWG file, when parsed in Revit, can force a stack-based buffer overflow. A malicious actor can leverage this vulnerability to execute arbitrary code in the context of the current process.
CVE-2024-23138 1 Autodesk 9 Autocad, Autocad Advance Steel, Autocad Architecture and 6 more 2025-01-28 7.8 High
A maliciously crafted DWG file when parsed through Autodesk DWG TrueView can be used to cause a Stack-based Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.
CVE-2024-37003 1 Autodesk 3 Advance Steel, Autocad, Civil 3d 2025-01-28 7.8 High
A maliciously crafted DWG and SLDPRT file, when parsed in opennurbs.dll and ODXSW_DLL.dll through Autodesk applications, can be used to cause a Stack-based Overflow. A malicious actor can leverage this vulnerability to cause a crash, read sensitive data, or execute arbitrary code in the context of the current process.
CVE-2024-4491 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4492 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4493 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4494 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4495 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4496 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4237 1 Tenda 2 Ax1806, Ax1806 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4238 1 Tenda 2 Ax1806, Ax1806 Firmware 2025-01-27 8.8 High
A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4239 1 Tenda 2 Ax1806, Ax1806 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4240 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4241 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4242 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4243 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4244 1 Tenda 2 W9, W9 Firmware 2025-01-27 8.8 High
A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-4245 1 Tenda 2 I21, I21 Firmware 2025-01-27 8.8 High
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.