Total
412 CVE
CVE | Vendors | Products | Updated | CVSS v3.1 |
---|---|---|---|---|
CVE-2023-23555 | 1 F5 | 13 Big-ip Access Policy Manager, Big-ip Advanced Firewall Manager, Big-ip Analytics and 10 more | 2025-03-26 | 7.5 High |
On BIG-IP Virtual Edition versions 15.1x beginning in 15.1.4 to before 15.1.8 and 14.1.x beginning in 14.1.5 to before 14.1.5.3, and BIG-IP SPK beginning in 1.5.0 to before 1.6.0, when FastL4 profile is configured on a virtual server, undisclosed traffic can cause the Traffic Management Microkernel (TMM) to terminate. Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated. | ||||
CVE-2013-1675 | 5 Canonical, Debian, Mozilla and 2 more | 20 Ubuntu Linux, Debian Linux, Firefox and 17 more | 2025-03-21 | 6.5 Medium |
Mozilla Firefox before 21.0, Firefox ESR 17.x before 17.0.6, Thunderbird before 17.0.6, and Thunderbird ESR 17.x before 17.0.6 do not properly initialize data structures for the nsDOMSVGZoomEvent::mPreviousScale and nsDOMSVGZoomEvent::mNewScale functions, which allows remote attackers to obtain sensitive information from process memory via a crafted web site. | ||||
CVE-2024-39864 | 2 Apache, Apache Software Foundation | 2 Cloudstack, Apache Cloudstack | 2025-03-19 | 9.8 Critical |
The CloudStack integration API service allows running its unauthenticated API server (usually on port 8096 when configured and enabled via integration.api.port global setting) for internal portal integrations and for testing purposes. By default, the integration API service port is disabled and is considered disabled when integration.api.port is set to 0 or negative. Due to an improper initialisation logic, the integration API service would listen on a random port when its port value is set to 0 (default value). An attacker that can access the CloudStack management network could scan and find the randomised integration API service port and exploit it to perform unauthorised administrative actions and perform remote code execution on CloudStack managed hosts and result in complete compromise of the confidentiality, integrity, and availability of CloudStack managed infrastructure. Users are recommended to restrict the network access on the CloudStack management server hosts to only essential ports. Users are recommended to upgrade to version 4.18.2.1, 4.19.0.2 or later, which addresses this issue. | ||||
CVE-2023-40261 | 1 Dieboldnixdorf | 1 Vynamic Security Suite | 2025-03-13 | 4.6 Medium |
Diebold Nixdorf Vynamic Security Suite (VSS) before 3.3.0 SR17, 4.0.0 SR07, 4.1.0 SR04, 4.2.0 SR04, and 4.3.0 SR02 fails to validate file attributes during the Pre-Boot Authorization (PBA) process. This can be exploited by a physical attacker who is able to manipulate the contents of the system's hard disk. | ||||
CVE-2023-20591 | 1 Amd | 132 Epyc 7003 Firmware, Epyc 7203, Epyc 7203 Firmware and 129 more | 2025-03-13 | 6.5 Medium |
Improper re-initialization of IOMMU during the DRTM event may permit an untrusted platform configuration to persist, allowing an attacker to read or modify hypervisor memory, potentially resulting in loss of confidentiality, integrity, and availability. | ||||
CVE-2021-3329 | 1 Zephyrproject | 1 Zephyr | 2025-03-11 | 9.6 Critical |
Lack of proper validation in HCI Host stack initialization can cause a crash of the bluetooth stack | ||||
CVE-2023-22466 | 1 Tokio | 1 Tokio | 2025-03-10 | 5.4 Medium |
Tokio is a runtime for writing applications with Rust. Starting with version 1.7.0 and prior to versions 1.18.4, 1.20.3, and 1.23.1, when configuring a Windows named pipe server, setting `pipe_mode` will reset `reject_remote_clients` to `false`. If the application has previously configured `reject_remote_clients` to `true`, this effectively undoes the configuration. Remote clients may only access the named pipe if the named pipe's associated path is accessible via a publicly shared folder (SMB). Versions 1.23.1, 1.20.3, and 1.18.4 have been patched. The fix will also be present in all releases starting from version 1.24.0. Named pipes were introduced to Tokio in version 1.7.0, so releases older than 1.7.0 are not affected. As a workaround, ensure that `pipe_mode` is set first after initializing a `ServerOptions`. | ||||
CVE-2025-2149 | 2025-03-10 | 2.5 Low | ||
A vulnerability was found in PyTorch 2.6.0+cu124. It has been rated as problematic. Affected by this issue is the function nnq_Sigmoid of the component Quantized Sigmoid Module. The manipulation of the argument scale/zero_point leads to improper initialization. The attack needs to be approached locally. The complexity of an attack is rather high. The exploitation is known to be difficult. The exploit has been disclosed to the public and may be used. | ||||
CVE-2021-22283 | 1 Abb | 38 Evd4, Evd4 Firmware, Rec615 and 35 more | 2025-03-07 | 6.2 Medium |
Improper Initialization vulnerability in ABB Relion protection relays - 611 series, ABB Relion protection relays - 615 series IEC 4.0 FP1, ABB Relion protection relays - 615 series CN 4.0 FP1, ABB Relion protection relays - 615 series IEC 5.0, ABB Relion protection relays - 615 series IEC 5.0 FP1, ABB Relion protection relays - 620 series IEC/CN 2.0, ABB Relion protection relays - 620 series IEC/CN 2.0 FP1, ABB Relion protection relays - REX640 PCL1, ABB Relion protection relays - REX640 PCL2, ABB Relion protection relays - REX640 PCL3, ABB Relion protection relays - RER615, ABB Remote Monitoring and Control - REC615, ABB Merging Unit- SMU615 allows Communication Channel Manipulation.This issue affects Relion protection relays - 611 series: from 1.0.0 before 2.0.3; Relion protection relays - 615 series IEC 4.0 FP1: from 4.1.0 before 4.1.9; Relion protection relays - 615 series CN 4.0 FP1: from 4.1.0 before 4.1.8; Relion protection relays - 615 series IEC 5.0: from 5.0.0 before 5.0.12; Relion protection relays - 615 series IEC 5.0 FP1: from 5.1.0 before 5.1.20; Relion protection relays - 620 series IEC/CN 2.0: from 2.0.0 before 2.0.11; Relion protection relays - 620 series IEC/CN 2.0 FP1: from 2.1.0 before 2.1.15; Relion protection relays - REX640 PCL1: from 1.0.0 before 1.0.8; Relion protection relays - REX640 PCL2: from 1.1.0 before 1.1.4; Relion protection relays - REX640 PCL3: from 1.2.0 before 1.2.1; Relion protection relays - RER615: from 2.0.0 before 2.0.3; Remote Monitoring and Control - REC615: from 1.0.0 before 2.0.3; Merging Unit- SMU615: from 1.0.0 before 1.0.2. | ||||
CVE-2024-38606 | 1 Linux | 1 Linux Kernel | 2025-03-06 | 7.1 High |
In the Linux kernel, the following vulnerability has been resolved: crypto: qat - validate slices count returned by FW The function adf_send_admin_tl_start() enables the telemetry (TL) feature on a QAT device by sending the ICP_QAT_FW_TL_START message to the firmware. This triggers the FW to start writing TL data to a DMA buffer in memory and returns an array containing the number of accelerators of each type (slices) supported by this HW. The pointer to this array is stored in the adf_tl_hw_data data structure called slice_cnt. The array slice_cnt is then used in the function tl_print_dev_data() to report in debugfs only statistics about the supported accelerators. An incorrect value of the elements in slice_cnt might lead to an out of bounds memory read. At the moment, there isn't an implementation of FW that returns a wrong value, but for robustness validate the slice count array returned by FW. | ||||
CVE-2024-40926 | 1 Linux | 1 Linux Kernel | 2025-03-06 | 5.5 Medium |
In the Linux kernel, the following vulnerability has been resolved: drm/nouveau: don't attempt to schedule hpd_work on headless cards If the card doesn't have display hardware, hpd_work and hpd_lock are left uninitialized which causes BUG when attempting to schedule hpd_work on runtime PM resume. Fix it by adding headless flag to DRM and skip any hpd if it's set. | ||||
CVE-2023-27115 | 1 Webassembly | 1 Webassembly | 2025-02-28 | 5.5 Medium |
WebAssembly v1.0.29 was discovered to contain a segmentation fault via the component wabt::cat_compute_size. | ||||
CVE-2020-27950 | 1 Apple | 4 Ipados, Iphone Os, Macos and 1 more | 2025-02-28 | 5.5 Medium |
A memory initialization issue was addressed. This issue is fixed in macOS Big Sur 11.0.1, watchOS 7.1, iOS 12.4.9, watchOS 6.2.9, Security Update 2020-006 High Sierra, Security Update 2020-006 Mojave, iOS 14.2 and iPadOS 14.2, watchOS 5.3.9, macOS Catalina 10.15.7 Supplemental Update, macOS Catalina 10.15.7 Update. A malicious application may be able to disclose kernel memory. | ||||
CVE-2023-40596 | 2 Microsoft, Splunk | 2 Windows, Splunk | 2025-02-28 | 7 High |
In Splunk Enterprise versions earlier than 8.2.12, 9.0.6, and 9.1.1, a dynamic link library (DLL) that ships with Splunk Enterprise references an insecure path for the OPENSSLDIR build definition. An attacker can abuse this reference and subsequently install malicious code to achieve privilege escalation on the Windows machine. | ||||
CVE-2023-26084 | 1 Arm | 1 Aarch64cryptolib | 2025-02-27 | 3.7 Low |
The armv8_dec_aes_gcm_full() API of Arm AArch64cryptolib before 86065c6 fails to the verify the authentication tag of AES-GCM protected data, leading to a man-in-the-middle attack. This occurs because of an improperly initialized variable. | ||||
CVE-2023-1513 | 3 Fedoraproject, Linux, Redhat | 3 Fedora, Linux Kernel, Enterprise Linux | 2025-02-25 | 3.3 Low |
A flaw was found in KVM. When calling the KVM_GET_DEBUGREGS ioctl, on 32-bit systems, there might be some uninitialized portions of the kvm_debugregs structure that could be copied to userspace, causing an information leak. | ||||
CVE-2022-48352 | 1 Huawei | 2 Emui, Harmonyos | 2025-02-24 | 7.5 High |
Some smartphones have data initialization issues. Successful exploitation of this vulnerability may cause a system panic. | ||||
CVE-2025-25947 | 2025-02-20 | 5.5 Medium | ||
An issue in Bento4 v1.6.0-641 allows an attacker to trigger a segmentation fault via Ap4Atom.cpp, specifically in AP4_AtomParent::RemoveChild, during the execution of mp4encrypt with a specially crafted MP4 input file. | ||||
CVE-2022-27493 | 1 Intel | 4 Lapbc510, Lapbc510 Firmware, Lapbc710 and 1 more | 2025-02-18 | 7.8 High |
Improper initialization in the firmware for some Intel(R) NUC Laptop Kits before version BC0076 may allow a privileged user to potentially enable an escalation of privilege via local access. | ||||
CVE-2024-26021 | 2025-02-13 | 2.3 Low | ||
Improper initialization in the firmware for some Intel(R) AMT and Intel(R) Standard Manageability may allow a privileged user to potentially enable information disclosure via local access. |